easy touch uric acid test strips
Product Name : Electronic High quality Household easy touch uric acid test strips For Elderly Care Automatic Sugar testing
Key words: Test for Elderly care ·High quality ·Household use·Uric acid testing strip
Introduction: Easy touch uric acid test strips (EUS-101) uses electrochemical biosensor technology. A whole blood sample is drawn by capillary action into a reaction zone on the strip automatically that will achieve a stable sample volume.It is used for quantitatively measuring uric acid in human peripheral blood or venous whole blood,mainly used in clinical diagnosis of hyperuricemia.
Product details
Place of Origin | China | Brand | LYSUN | |
Model Number | GUM-101 | Methodology | Electrochemistry method | |
Certificates available | CE/ISO9001 | Measuring Range | Glu:20-600mg/dL(1.1-33.3mmol/L);UA:3-20mg/dL(179-1190umol/L) | |
Warranty Period | 2years | Blood Specimen | whole blood (Fresh capillary or venous) | |
Power Supply | One 2.0 CR2032 | Memory | 100records ( date & time ) | |
Meter Shelf Life | 5years | Meter Size | 84.7mm*53mm*18mm(L*W*H) | |
Test Strip Shelf Life | 2years | Meter Storage Conditions | 0-55℃;≤90%RH | |
Instrument Classification | Class II | System operating Conditions | 10-40℃;0-90% RH; Height ≤ altitude 2000m | |
Measuring Unit | mmol/L;mg/dL,umol/L | Test Strip Conditions | 2-30℃;≤90%RH | |
Weight | 50g | Automatic Shut Off | 1 min after displaying Results | |
Battery Endurance | Approx.1,000tests | After-sale service | Online Tehnical Support |
Packaging & Delivery
Product name : Easy touch uric acid test strips
Selling Units: 10 strips of vial、25 strips of vial、25 strips of box、50 strips of box
Single item: 4*4*6.5cm
Package: 60boxes/inner carton ,4inner boxes(240boxes)/Master Carton
Carton size: 44*27*30.5 cm
Single box gross weight:28g
G.W. per carton :8.7kgs
CUSTOMIZE:
OEM accepted
STORAGE & HANDLING
• Store the test strip at a temperature within 1 ~30 ℃ under the dry place (humidity less than 90% ).
• Do not dispose test strip in high humidity or direct sunlight. Don’t freeze the strip.
• Cap the strip vial immediately after removing a strip.
• The test strip is for single use only. Never reuse a test strip that had either blood or solution. Do not bend, cut or fold the strip.
• With clean and dry hands to handle, remove, touch and insert the strip gently.
• Test strip must be used within 3 months after the date the vial was first opened. Write the opening date on the vial label after opening.
• Expiry Date: Unopened product is valid for 24 months.
•Automatic 7, 14 & 28 day averages
•Store up to 100 results with date and time
CODING PROCEDURE
Matching the code on the analyzer and the code which printed on the test strip vial is essential to obtain accurate results.Each time you test, make sure the matched code number. For details, please read the operating instructions for analyzer.
TEST CONDITIONS
Make sure that the test temperature within (8 ~ 37) ℃, humidity test is not greater than 80%. Please avoid to eat food containing reducing agents such as vitamin C as far as possible when test.
CAUTION: If there is a bigger difference between the preservation temperature and the test temperature, please let the temperature of the test strip and the analyzer reach the test temperature before the test (suggested to balance more than 30 minutes)
Uric acid Testing
Step 1: Wash your hands with warm, soapy water and disinfect the puncture site using the 75% alcohol. Dry them thoroughly. Step 2: Remove a test strip and recap the vial immediately. Insert the test strip, contact bars end first and facing up, into the test port.Push the test strip in as far as it will go. The analyzer turns on automatically, at the same time a squeaking "di" prompt. Be sure the analyzer and test strip code match.
Step 3: When the flashing apply blood symbol appears on the screen, touch and hold the drop of blood to the narrow channel in the side edge of the test strip. Keep holding the blood drop to the side edge of the test strip until the confirmation window is full.
Step 4: Your Uric acid test result will appear after the analyzer counts down from 30 to 1, and write down the test result. Analyzer automatic shutdown with squeaking "di" prompt when pull out the test strip.
Our Company
FAQ:
Q: Where is you factory located? How can I visit there?
A: Our factory is located in Hangzhou, Zhejang Province, China.Which is quite near to Shanghai or Ningbo port . For the cargo delivery ,Whatever by sea or air transportation .It’s very convenient .
Q:Do you support OEM and ODM.
A: Yes .OEM and ODM are both considerable and workable.
MOQ: 500 units device,1000 boxes test strips.
Q: Are you trading company or manufacturer ?
A: We are manufacturer. Our factory is located in Hangzhou City ,Zhejiang Province .China .
We are in very good advantages for controlling cost and very strictly quality management system to make sure our products in perfect shape and guanrantee quality before delivery .
Q: Would you send me a sample to evaluate the quality before I order?
A: Yes, We also suggest customers to make evaluation before bulk ordering.
According the sample policy ,we may charge in advance the cost of samples .
But ,Actually the samples are finally free to you . Sample cost can be deducted from your bulk order payment.
Q: How does your factory do regarding quality control?
A:1) Very strict quality management system on production line
2) 100% QC inspection before shipment.
Q: What about the warranty?
A: Warranty for meters: 24 Months
Shelf life for meters under electrochemical method is 5 Years; For photochemical meters 4years
Shelf life for electrochemical test strip: 24 Months
Shelf life for dry chemistry test strip: 12 Months
Q: What is your general international express?
A: FedEx, DHL, UPS, EMS … are optionable