CE Approved Dry Biochemistry Analyzer

CE Approved Dry Biochemistry Analyzer

Dry bioanalyzer Product Introduction CE Approved Dry bioanalyzer is intended for the quantitative determination of Total Cholesterol (TC), High Density Lipoprotein Cholesterol (HDL),Triglycerides (TG), Uric Acid (UA), Creatinine (CR) and Urea (UR), Blood Ketone (KET) in capillary blood, venous...

Product Introduction

Dry bioanalyzer

Dry bioanalyzer

Methodology

Reflectance Photometer

Measurement Range

UA:0.090mmol/L~1.200mmol/L(1.51mg/dL~20.17mg/dL)

CR:0.044mmol/L~1.320mmol/L(0.50mg/dL~14.93mg/dL)

UR:0.90mmol/L~40.00mmol/L(5.41mg/dL~240.2mg/dL)

TC:2.59mmol/L-12.93mmol/L(100mg/dL-500mg/dL)

HDL:0.39mmol/L-2.59mmol/L(15mg/dL-100mg/dL)

TG:0.51mmol/L-7.34mmol/L(45mg/dL-650mg/dL)

KET:0.02mmol/L~6.00mmol/L(0.21mg/dL~62.46mg/dL)

Specimen

Whole Blood(capillary and venous),plasma and serum

Power Source

1200mAh built-in lithium battery

Battery Endurance

After cycle charge 300 times, electric quantity reduce 30%

Units of Measurement

mmol/L, mg/dL

Memory

500 records

Automatic Shut Off

5 minutes after last use

Meter Size

135*66*19mm(L*W*H)

Weight

90g

Meter Storage Conditions

0-55℃≤ 90% RH

System Operating Conditions

10-35℃≤ 90%RHaltitude 2000m

Test Strip Storage Conditions

230℃;≤ 90% RH

Warranty Period

2 years

Meter Shelf Life

4 years

Test Strip Shelf Life

1 year

Product Introduction

CE Approved Dry bioanalyzer is intended for the quantitative determination of Total Cholesterol (TC), High Density Lipoprotein Cholesterol (HDL),Triglycerides (TG), Uric Acid (UA), Creatinine (CR) and Urea (UR), Blood Ketone (KET) in capillary blood, venous whole blood, plasma and serum. CE Approved Dry bioanalyzer provides results. Dry bioanalyzer can store up to 500 results and records.

Limitation:

High concentrations of uric acid and ascorbic acid can lead to low measurements. Anticoagulants,such as heparin and EDTA,are recommended for use with venous whole blood. Do not use EDTA plasma,which lead to higher results. Do not use other anticoagulants, such as iodoacetate,sodium citrate or those containing fluoride. Arterial blood isn’t recommended for use.Hemolyzed blood or thrombolytic therapy blood may lower the results. Venous occlusion may increase the results and is not recommended to draw the blood

Lysun Profile

Our enterprise has our own professional R&D team focusing on the diagnostic technology research. It is a biomedical high-tech enterprise specializing in the research and development, production and sales of in vitro diagnostic reagents and supporting instruments.It have grown rapidly and has become a leader in the field of POCT.

Lysun Certificate RFS-101+LPS-101_25PCS

 

 