Movable Dry Biochemistry Analyzer

Movable Dry Biochemistry Analyzer

Dry bioanalyzer Product Introduction Movable Dry bioanalyzer is intended for the quantitative determination of Total Cholesterol (TC), High Density Lipoprotein Cholesterol (HDL),Triglycerides (TG), Uric Acid (UA), Creatinine (CR) and Urea (UR), Blood Ketone (KET) in capillary blood, venous whole...

Product Introduction

Dry bioanalyzer

Dry bioanalyzer

Methodology

Reflectance Photometer

Measurement Range

UA:0.090mmol/L~1.200mmol/L(1.51mg/dL~20.17mg/dL)

CR:0.044mmol/L~1.320mmol/L(0.50mg/dL~14.93mg/dL)

UR:0.90mmol/L~40.00mmol/L(5.41mg/dL~240.2mg/dL)

TC:2.59mmol/L-12.93mmol/L(100mg/dL-500mg/dL)

HDL:0.39mmol/L-2.59mmol/L(15mg/dL-100mg/dL)

TG:0.51mmol/L-7.34mmol/L(45mg/dL-650mg/dL)

KET:0.02mmol/L~6.00mmol/L(0.21mg/dL~62.46mg/dL)

Specimen

Whole Blood(capillary and venous),plasma and serum

Power Source

1200mAh built-in lithium battery

Battery Endurance

After cycle charge 300 times, electric quantity reduce 30%

Units of Measurement

mmol/L, mg/dL

Memory

500 records

Automatic Shut Off

5 minutes after last use

Meter Size

135*66*19mm(L*W*H)

Weight

90g

Meter Storage Conditions

0-55℃≤ 90% RH

System Operating Conditions

10-35℃≤ 90%RHaltitude 2000m

Test Strip Storage Conditions

230℃;≤ 90% RH

Warranty Period

2 years

Meter Shelf Life

4 years

Test Strip Shelf Life

1 year

Product Introduction

Movable Dry bioanalyzer is intended for the quantitative determination of Total Cholesterol (TC), High Density Lipoprotein Cholesterol (HDL),Triglycerides (TG), Uric Acid (UA), Creatinine (CR) and Urea (UR), Blood Ketone (KET) in capillary blood, venous whole blood, plasma and serum. Movable Dry bioanalyzer provides results. Dry bioanalyzer can store up to 500 results and records.

Quality Control 

Each lab should use its own standards and procedures for performance. Test known specimens/controls at each of the following events in accordance with local, state, and/or federal regulations or accreditation requirements: 

• When a new package of test strips is opened 

• When a new operator uses the meter 

• When test results seem inaccurate 

• After performing maintenance or service on the meter If quality control tests do not provide expected results, perform the following checks: 

• Ensure that the test strips used are not expired. 

• Ensure that the test strips are fresh from a new canister or package. 

• Ensure that the controls are not expired. 

• Repeat the test to ensure no errors were made during the test



 

 

 